Status ketersediaan: | |
---|---|
Kuantiti: | |
IMAXS500VDC
EMAX
Model | IMAXS1250 | |
parameter keluaran | Kapasiti Maks | 50kW*2 |
Nombor Litar | 2 saluran | |
Parameter Gelung | 2 saluran | |
Julat Voltan | DC50-500V | |
Voltan Ternilai | DC500V | |
Julat Semasa | 0-100A | |
Kelantangan | 50kw*2 | |
Riak Voltan | ≤0.5%FS(skala penuh) | |
Riak semasa | ≤0.5%FS(skala penuh) | |
Ketepatan penstabilan voltan | ≤±0.5% FS(Beban Perintang FS) | |
Ketepatan arus mantap | ≤±1% FS(Beban Perintang FS) | |
Peraturan Talian | ±0.1% FS | |
Peraturan Beban | ±0.3% FS | |
Masa Kenaikan Keluaran | <100mS(10%-90%)Ujian beban rintangan | |
Masa Tindak Balas Sementara | <10s | |
Mod Sambungan | Terminal | |
Memuat naik Kejutan | ≤0.5% nilai undian,masa≤1s | |
Penurunan serta-merta dengan beban | ≤0.5% nilai undian,masa≤500ms | |
Kekuatan penebat, rintangan penebat | Input ke perumahan:20MΩ 500VDC; Output ke perumahan:20MΩ 500VDC | |
Rintangan anti-penimbunan semula | Dengan rintangan Anti-penimbunan semula | |
Gelung Kawalan | voltan | 380V±15% |
Kaedah input | Tiga fasa empat wayar +PE | |
Kekerapan | 50Hz±10% | |
Mod Kawalan | Skrin sentuh tempatan + pemula wayar keras jauh dan kotak kawalan berhenti kecemasan | |
Mod Sambungan | Terminal | |
Mod Bekalan Kuasa | Luaran | |
Selongsong | Mod Kerja | Kerja berterusan |
Gred Penebat | Tahap F | |
Mod Penyejukan | Kipas kelajuan pintar, penyejukan udara paksa, udara hadapan, selepas udara. | |
bising | ≤65dB pada 1 meter | |
Saiz | Kira-kira 500mm * 700mm * 1000mm (lebar * kedalaman * ketinggian) | |
Berat badan | Kira-kira 160kg | |
Kaedah bergerak | Terdapat kastor di bahagian bawah dan pemegang di hadapan untuk pergerakan mudah. | |
Fungsi Pertahanan | Pengehadan voltan, pengehadan arus, voltan lebih, arus lebih, beban lebih suhu, litar pintas, Output terputus perlindungan, fungsi nyahcas sendiri tutup | |
Fungsi Lain | Kedua-dua input dan output mempunyai fungsi pra-pengecasan |
Model | IMAXS1250 | |
parameter keluaran | Kapasiti Maks | 50kW*2 |
Nombor Litar | 2 saluran | |
Parameter Gelung | 2 saluran | |
Julat Voltan | DC50-500V | |
Voltan Ternilai | DC500V | |
Julat Semasa | 0-100A | |
Kelantangan | 50kw*2 | |
Riak Voltan | ≤0.5%FS(skala penuh) | |
Riak semasa | ≤0.5%FS(skala penuh) | |
Ketepatan penstabilan voltan | ≤±0.5% FS(Beban Perintang FS) | |
Ketepatan arus mantap | ≤±1% FS(Beban Perintang FS) | |
Peraturan Talian | ±0.1% FS | |
Peraturan Beban | ±0.3% FS | |
Masa Kenaikan Keluaran | <100mS(10%-90%)Ujian beban rintangan | |
Masa Tindak Balas Sementara | <10s | |
Mod Sambungan | Terminal | |
Memuat naik Kejutan | ≤0.5% nilai undian,masa≤1s | |
Penurunan serta-merta dengan beban | ≤0.5% nilai undian,masa≤500ms | |
Kekuatan penebat, rintangan penebat | Input ke perumahan:20MΩ 500VDC; Output ke perumahan:20MΩ 500VDC | |
Rintangan anti-penimbunan semula | Dengan rintangan Anti-penimbunan semula | |
Gelung Kawalan | voltan | 380V±15% |
Kaedah input | Tiga fasa empat wayar +PE | |
Kekerapan | 50Hz±10% | |
Mod Kawalan | Skrin sentuh tempatan + pemula wayar keras jauh dan kotak kawalan berhenti kecemasan | |
Mod Sambungan | Terminal | |
Mod Bekalan Kuasa | Luaran | |
Selongsong | Mod Kerja | Kerja berterusan |
Gred Penebat | Tahap F | |
Mod Penyejukan | Kipas kelajuan pintar, penyejukan udara paksa, udara hadapan, selepas udara. | |
bising | ≤65dB pada 1 meter | |
Saiz | Kira-kira 500mm * 700mm * 1000mm (lebar * kedalaman * ketinggian) | |
Berat badan | Kira-kira 160kg | |
Kaedah bergerak | Terdapat kastor di bahagian bawah dan pemegang di hadapan untuk pergerakan mudah. | |
Fungsi Pertahanan | Pengehadan voltan, pengehadan arus, voltan lebih, arus lebih, beban lebih suhu, litar pintas, Output terputus perlindungan, fungsi nyahcas sendiri tutup | |
Fungsi Lain | Kedua-dua input dan output mempunyai fungsi pra-pengecasan |